Danfoss Scroll Compressor 3PH R407C R22 PVE Oil Stub Tube - HRP047T4LP6

Danfoss Scroll Compressor 3PH R407C R22 PVE Oil Stub Tube

Part Number: HRP047T4LP6

Danfoss Scroll Compressor 3PH R407C R22 PVE Oil Stub Tube

Part Number: HRP047T4LP6
Danfoss

Sign in to your Aire-Biz account to view pricing and stock levels.

Sign in

Not an Airefrig customer? Complete our online account application form here to apply for a credit account.

  • Danfoss H-Series Scroll Compressors are 100% gas cooled & fitted with an automatic reset line break protector mounted internally on the motor windings. 

    The internal protectors respond to over-current, overheating & are designed to interrupt motor current under a variety of fault conditions such as failure to start, running overload & fan failure etc. 

    If the internal overload protector trips it must cool down to approximately +60 degrees Celsius to reset. (Depending on the ambient temperature this may take up to several hours) 

    Three Phase Sequence & Reverse Rotation Protection 

    The compressor will only operate properly with the correct rotation. If a three phase compressor is wired incorrectly it will run but will have excessive noise, no pressure differential between suction & discharge, plus the suction will become warmer rather than cooler. 

    The smaller range of Danfoss H-Series scroll compressors (up to HLP075) are able to run in reverse rotation safely for up to 150 hours without damaging the compressor, however phase monitors are still recommended. 

    The larger range of Danfoss H-Series scroll compressors (HLP078 onwards) should never be run in reverse. Danfoss recommends phase rotation protection should always be fitted to prevent these compressors from operating in reverse rotation. 

    Single Phase Compressors – Reverse Rotation 

    Brief power interruptions may cause reverse rotation of single phase scroll compressors. The internal protection will stop the compressor & once cooled down will restart with correct rotation. 

    Crankcase heaters are recommended on all stand-alone compressors & split systems. The heater should be energised for a minimum of 12 hours before initial start up (compressor service valves opened) & must remain energised whenever the compressor is off. 

    External High Pressure Switches are required for HCP094,109,120 scroll compressors as these models are not equipped with internal pressure relief valves. 

    Note: Crankcase heater is not supplied with compressor & should be purchased separately if required.

     

  • General Specifications
    Nominal HP4 HP
    Displacement11.2 m³/Hr
    Swept Volume64.07 cm³
    Suction Line ConnectionStub Tube 7/8" ODF
    Discharge Line ConnectionStub Tube 1/2" ODF
    Weight31.16 kg
    Oil Charge1.33 L
    Oil TypePVE Oil 320HV
    Electricsround electrical box with spade terminals
    Electrical Specifications
    Voltage380-415/3/50
    Motor Type3PH
    Max Continuous Current12 amps
    Locked Rotor Amps50 amps
    Rated Load Amps7.7 amps
    Crankcase Heater 140watt, 230volt

    1. Crankcase Heaters are not supplied with compressors & should be purchased separately if required

  • ContactorMC18B240V
    Thermal OverloadMT323K13
    Electronic OverloadGMP223P22A
    Crankcase Heater120Z0055
  • danfoss_scroll_dim_1

    Units Dimensions (mm)
    D165
    H439
    H1275
    H2405
  • R22
    Cond Temp (°C)Evaporating Temperature (°C)
    -15-10-5057.210
    45Capacity (w)5201652580879866118381276213982
    Input (w)2991292528822854283128212806
    Current (Amps)65.85.75.75.75.65.5
    50Capacity (w)4693602275689307112181210813279
    Input (w)3406329932273181315431453135
    Current (Amps)6.66.36.26.16.16.16
    55Capacity (w)542569728691105591142312556
    Input (w)374636343561351635043493
    Current (Amps)6.96.76.66.66.66.5

    Note:

    Rating Conditions 11.1k Superheat, 8.3K Subcooling
    R407C
    Cond Temp (°C)Evaporating Temperature (°C)
    -15-10-5057.210
    45Capacity (w)4938622077369510115661260613929
    Input (w)2943292629112891286028392813
    Current (Amps)6.826.846.856.836.746.656.54
    50Capacity (w)4573578672238907108631185413115
    Input (w)3359334033253307328132633240
    Current (Amps)7.377.397.417.397.37.217.1
    55Capacity (w)532266818276101311107312271
    Input (w)381137973782376137463728
    Current (Amps)88.038.017.937.847.73

    Note:

    Rating Conditions 11.1k Superheat, 8.3K Subcooling