  • Enthalpy Semi-Hermetic Flat Base Condensing Units

    Airefrig Australia’s range of Enthalpy condensing units is one of the highest quality units available for the Australian market. The condensing units have many standard fitted features, previously being options.

    The condensing units are rated to 43 ambient and are fitted with a fan speed controller. This means they can be applied in the hot climate of far North Queensland to the cooler areas of Tasmania.

    The Enthalpy condensing unit is the most complete condensing unit available saving time in installation for contractors.

    Standard Fitted Features:

    • Bitzer Ecoline Compressor with Oil Sight Glass
    • Crankcase Heater
    • OLC-K1 Oil Level Monitor (4 Cylinder Compressors)
    • Service Shut Off Valves
    • HP/LP Control
    • Gomax Flexible Control Hoses
    • Liquid Line Drier & Sight Glass
    • Oil Separator (Pre-charged with POE Oil)
    • Liquid Receiver
    • Galvanised Black Powder Coated Unit Base
    • Supercoat Condenser Treatment (5000 Hour Salt Spray Test)
    • Discharge Vibration Eliminator
    • ebmpapst Condenser Fans – Single Phase
    • Saginomiya Condenser Fan Speed Controller
    • 3PH Contactor & Electronic Motor Protection Relay
    • Phase Loss & Phase Imbalance Protection
    • Pre - Wired Back to Junction Box
    • Nitrogen Holding Charge

    Options:
    • Suction Accumulator (factory fitted) (Not available for 2JES07Y1003)
    • Unit Weatherproof Cover (knockdown form)

  • Condensing Unit Specifications
    Weight175 Kg
    Liquid Line Connection5/8 "
    Suction Line Connection7/8 "
    Receiver Capacity R404A8.1 Kg
    Compressor
    Nominal HP3 HP
    Max Continuous Current8.6 Amps
    Voltage380-400V / 3 / 50Hz
    Motor TypeDOL
    Crankcase Heater230V / 1 / 50Hz 120w
    Fan Motors
    Total FLA1.55 Amps
    Quantity1
    Diameter450 mm
    Voltage230V / 1 / 50Hz
  • Compressor Model2DES3Y
    Compressor ContactorMC12B240V
    Compressor Electronic OverloadGMP223P22A
    Circuit Breaker Control CircuitPLSMD10
    Oil Separator (Internal Float)EOS1005
    Liquid Receiver1320315A
    Receiver Outlet ValveR051FA8DS
    Receiver Outlet Gasket020002800
    Unit Electrical BoxAIRENTENCL
    Liquid Line Drier / Sight Glass ComboCSG165S
    Unit Start Delay TimerICM105
    Dual Pressure ControlDNSD306X
    Condenser Fan Model (ebm)S4E450AU0337
    Fan Speed ControllerRGEZ1N45MFQ1
  • Enthalpy_Semi-Herm-C
  • FBTDBIT1FAN(010114)
  • R404A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    32183425193308420852256357760889791045912046
    3815752202292137424665569268248059938810805
    43135219292591334441895128616072818485

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R507
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    32183425193308420852256357760889791045912046
    3815752202292137424665569268248059938810805
    43135219292591334441895128616072818485

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R134A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -25-20-15-10-50510
    3220672773360345695679694083619943
    3818692528330342055241641777409212
    4317062327305739064879598472268607

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Fan speed controller will require to be adjusted to suit R134a refrigerant at time of commissioning.
    Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R449A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    32141520252754361446175773709185791024512089
    3812121771244532414172524764747860940811120
    4310441564219029343805481259637262871210309

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R513A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -25-20-15-10-50510
    32229430223869484559547205859810140
    3820712748353444385465662279109331
    4318902522325741025061614073398660

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Fan speed controller will require to be adjusted to suit R134a refrigerant at time of commissioning.
    Fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
  • Notes for Commissioning:

    Set Dual Pressure Control to suit application.
    Set Fan Speed Control to suit application (ie: R134a).
    Adjust Motor Current Overload to suit application.
    Unit delivered with 1200 kpa nitrogen holding charge.
    Remove/adjust transport protection (Bitzer comps only).
    Check integrity of electrical connections/terminations.
    Check integrity of fixing screws & bolts etc.