Enthalpy TD Semi Cond Unit-3Ø 5HP. CMRC CapCon. - TD4FES5MP273CM

Enthalpy TD Semi Cond Unit-3Ø 5HP. CMRC CapCon.

Part Number: TD4FES5MP273CM

Enthalpy TD Semi Cond Unit-3Ø 5HP. CMRC CapCon.

Part Number: TD4FES5MP273CM
Enthalpy

Sign in to your Aire-Biz account to view pricing and stock levels.

Sign in

Not an Airefrig customer? Complete our online account application form here to apply for a credit account.

  • Enthalpy TD Semi-Hermetic Condensing Units

    Airefrig Australia’s range of Enthalpy condensing units is one of the highest quality units available for the Australian market. The condensing units have many standard fitted features, previously being options.

    The condensing units are rated to 43 ambient and are fitted with a fan speed controller. This means they can be applied in the hot climate of far North Queensland to the cooler areas of Tasmania.

    The Enthalpy condensing unit is the most complete condensing unit available saving time in installation for contractors.

    Standard Fitted Features:

    • Weatherproof White Powder coated unit casing
    • Semi-Hermetic Bitzer Compressors
    • Compressor oil sight glass
    • Crankcase Heater
    • HP/LP Control
    • Gomax Flexible Control Hoses
    • Liquid Line Drier & Sight Glass
    • Oil separator (Pre-charged with Poe oil)
    • Liquid Receiver• Supercoatcondenser treatment (5000 Hour Salt Spray Test)
    • Top Discharge High Ambient Condenser
    • Space saving unit design (Can be installed into a corner or back to back)
    • ebm-papst condenser Fans – single Phase
    • Saginomiya Condenser Fan Speed Controller
    • 3PH Contactor & Electronic Motor Protection Relay
    • Phase Loss & Phase Imbalance Protection
    • Dust & Weatherproof Electrical Box
    • Pre-Wired Back to Electrical Box
    • 1.22mm (18G) Interconnecting Copper Pipe Work
    • Pre-Drilled ready to fit IPW series isolating switch
    • Discharge Vibration Eliminator
    • Suction Accumulator
  • Condensing Unit Specifications
    Weight280 Kg
    Liquid Line Connection5/8 "
    Suction Line Connection1-1/8 "
    Receiver Capacity R404A12 Kg
    Compressor
    Nominal HP5 HP
    Max Continuous Current10.8 Amps
    Voltage380-400V / 3 / 50Hz
    Motor TypeDOL
    Crankcase Heater230V / 1 / 50Hz 120w
    Fan Motors
    Total FLA6 Amps
    Quantity2
    Diameter500 mm
    Voltage230V / 1 / 50Hz
  • Compressor Model4FES5Y
    Compressor ContactorMC22B240V
    Compressor Electronic OverloadGMP223P22A
    Circuit Breaker Control CircuitPLSMD4
    Circuit Breaker Condenser FansPLSMD16
    Oil Separator (Internal Float)EOS1007
    Liquid Receiver1320620A
    Receiver Outlet ValveR051FB2DS
    Receiver Outlet Gasket020002800PK
    Unit Electrical BoxAIR50650
    Liquid Line Drier / Sight Glass ComboCSG165S
    Suction Accumulator1010853P
    Unit Start Delay TimerICM105
    Compressor CRII Solenoid Valve34760147
    Compressor Oil Monitor34731602
    Low Pressure ControlSNSC106X
    High Pressure ControlSNSC130X
    CM-RC-01 Control Module34702850
    Compressor Head Cooling FanW1G130AA2511
    Low Pressure Transducer (Carel)SPKT0143P0
    High Pressure Transducer (Carel)SPKT0033P0
    Condenser Fan Model (ebm)S4E500AM0301
    Fan Speed ControllerRGEZ1Q45MFQ1
    TD Case ModelMP27
  • Enthalpy_TD_MP27
  • (B33)TD5HPto7HP Units-AC-CRII-DN33 (21
  • R404A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    3226603533457958157255891310798129191527817880
    382374317041245247655480549755116591377216093
    432126285937334762595573228867105921249814582

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Compressor fitted with CRII 10-100% capacity regulation (CM-RC-01 module controlled by Carel DN33) & head cooling fan
    1 phase AC fans are speed controlled via Saginomiya RGEZ controller
    Saginomiya fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Fitted with suction accumulator, liquid receiver, liquid line drier & sight glass combo
    Fitted with oil separator (internal float)
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R507
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    3226603533457958157255891310798129191527817880
    382374317041245247655480549755116591377216093
    432126285937334762595573228867105921249814582

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Compressor fitted with CRII 10-100% capacity regulation (CM-RC-01 module controlled by Carel DN33) & head cooling fan
    1 phase AC fans are speed controlled via Saginomiya RGEZ controller
    Saginomiya fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Fitted with suction accumulator, liquid receiver, liquid line drier & sight glass combo
    Fitted with oil separator (internal float)
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R449A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -40-35-30-25-20-15-10-505
    3220312870388450946521818510108123131482017653
    381765253234674586591174599251113091364916291
    431552226131294173541168628544104751267315153

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Compressor fitted with CRII 10-100% capacity regulation (CM-RC-01 module controlled by Carel DN33) & head cooling fan
    1 phase AC fans are speed controlled via Saginomiya RGEZ controller
    Saginomiya fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Fitted with suction accumulator, liquid receiver, liquid line drier & sight glass combo
    Fitted with oil separator (internal float)
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R513A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -25-20-15-10-50510
    323005397351296493808399171200914377
    382695359046595921739190831101413195
    432432326742655441681283881018412210

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Compressor fitted with CRII 10-100% capacity regulation (CM-RC-01 module controlled by Carel DN33) & head cooling fan
    1 phase AC fans are speed controlled via Saginomiya RGEZ controller
    Saginomiya fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Saginomiya fan speed controller will require to be adjusted to suit R513a refrigerant at time of commissioning.
    Fitted with suction accumulator, liquid receiver, liquid line drier & sight glass combo
    Fitted with oil separator (internal float)
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.
    R134A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -25-20-15-10-50510
    322707363547556091766394911159613995
    382429329143335576703887381069112917
    43219230023980514565178110994012022

    Note:

    Nominal ratings should be used as a guide, based on 20 degree Celsius return vapour and inherent liquid subcooling.
    Compressor fitted with CRII 10-100% capacity regulation (CM-RC-01 module controlled by Carel DN33) & head cooling fan
    1 phase AC fans are speed controlled via Saginomiya RGEZ controller
    Saginomiya fan speed controller is set for continuous running @ low speed, select fan OFF option at low speed in low ambient applications to prevent over condensing.
    Saginomiya fan speed controller will require to be adjusted to suit R134a refrigerant at time of commissioning.
    Fitted with suction accumulator, liquid receiver, liquid line drier & sight glass combo
    Fitted with oil separator (internal float)
    Requires additional cooling &/or return vapour limitations - Contact Airefrig Australia for further information.

My Comparison List

Compare Clear all
Sorry, you can only compare products from the same category.