Optyma Slim Condensing Unit - Med Temp - 3Ø 7HP - OPMPVE108MLW10E

Optyma Slim Condensing Unit - Med Temp - 3Ø 7HP

Part Number: OPMPVE108MLW10E

Optyma Slim Condensing Unit - Med Temp - 3Ø 7HP

Part Number: OPMPVE108MLW10E
Danfoss

Sign in to your Aire-Biz account to view pricing and stock levels.

Sign in

Not an Airefrig customer? Complete our online account application form here to apply for a credit account.

  • Danfoss Optyma Slim Pack Condensing Units

    With Danfoss, you get more than reliable solutions for cold rooms. Contractor-friendly products built with market leading expertise that are tailored to suit the local ambient conditions and regulations to save on installation and maintenance. Make the right choice for optimum protection of perishables, efficient operation and long lifespan.

    Main Product Features

    Outdoor Applications

    • Weatherproof Housing IP54
    • Robust and resistant to corrosion
    • Compact design
    • Crankcase Heater
    • Service Shut Off Valves

    Micro Channel Condenser Coil

    • Easy and fast cleaning
    • Less refrigerant charge
    • Longer life time
    • High Efficiency

    Externally mounted Service Ports

    • Fast and easy installation
    • Quick connections of suction & liquid lines
    • Shut off valves on receiver
    • Service valves with ports for easy servicing

    Standard Features

    • Weatherproof Housing IP54
    • Suitable for R404A/R507,R449A/R448A, R513A & R134a Refrigerants
    • Dedicated Low or Medium Temperature Units
    • Danfoss Hermetic & Scroll Compressors
    • Compressor Oil Sight Glass
    • Service Shut Off Valves
    • Fan Speed Controller
    • Dual Pressure Control
    • Drier & Sight Glass
    • Liquid Receiver
    • Pre-wired
  • Condensing Unit Specifications
    Weight88 Kg
    Liquid Line Connection1/2 "
    Suction Line Connection7/8 "
    Receiver Capacity6.2 L
    Compressor
    Nominal HP7 HP
    Max Continuous Current16 Amps
    Locked Rotor Amps87 Amps
    Voltage400V / 3 / 50Hz
    Motor TypeDOL
    Crankcase Heater240V / 1 / 50Hz 70w (fitted standard from Jan 2023)
    Fan Motors
    Total FLA0.97 Amps
    Quantity1
    Diameter500 mm
    Voltage230V / 1 / 50Hz
  • Circuit Breaker118U3874
    Comp Contactor118U3896
    Comp Overload118U3878
    CompressorMLZ048T4LC9A
    Condenser118U5219
    Crankcase Heater120Z5040
    Fan BladeRefer to Technical Guide
    Fan Grille/Guard118U3485
    Fan Motor + CapacitorRefer to Technical Guide
    Fan Speed ControlRefer to Technical Guide
    Filter DrierDML164
    HP/LP Control60539766
    Seq Phase Relay118U3882
    Sight GlassSGP12N
  • danfoss_optyma_b3
  • danfoss_optyma_slim_2022-10-11_w4
  • R404A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -20-15-10-50510
    32714786531032112168142091645918932
    3862487596908710742125801462216892
    435457667180119504111721304115144

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
    R507
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -20-15-10-50510
    32714786531032112168142091645918932
    3862487596908710742125801462216892
    435457667180119504111721304115144

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
    R134A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -15-10-50510
    32529866418223100331206214299
    3848896140762093231123613349
    4345485714710487091052012525

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
    Fan speed controller will require to be adjusted to suit R134a at time of commissioning.
    R513A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -15-10-50510
    32565170028566103591239014669
    3851296397786095351143513571
    4346835877725388261061312627

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
    Fan speed controller will require to be adjusted to suit R134a at time of commissioning.
    R449A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -20-15-10-50510
    32679083871019012212144591693919664
    3860787531917411021130811536517889
    43679582949985118801399116336

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
    R448A
    Ambient (°C)Refrigeration Capacity (w)
    Evaporating Temperature (°C)
    -20-15-10-50510
    32679083871019012212144591693919664
    3860787531917411021130811536517889
    43679582949985118801399116336

    Note:

    Nominal ratings should be used as a guide, based on EN13215 10K Superheat & inherent liquid subcooling.
  • Micro Channel Heat Exchanger technology | A whole new level of system efficiency

My Comparison List

Compare Clear all
Sorry, you can only compare products from the same category.